西西人体www303sw大胆高清-亚洲一区自拍高清亚洲精品-久久精品无码一区二区无码-国产高潮流白浆免费观看-日本精品少妇一区二区三区

全國服務咨詢熱線:

15618996225

當前位置:首頁  >  產品中心  >  太赫茲  >  太赫茲功率計  >  Mm-Wave power meter高靈敏度毫米波功率計

高靈敏度毫米波功率計

簡要描述:高靈敏度毫米波功率計Features
0.01-220 GHz operating frequency
High sensitivity
Up to 55 dB dynamic range (0.1uW-30mW)
Small measuring time (< 1 sec)
RS-232, GPIB interface
SCPI protocol

  • 產品型號:Mm-Wave power meter
  • 更新時間:2025-03-12
  • 訪  問  量:1016

產品簡介

品牌其他品牌產地類別進口
應用領域農林牧漁,電子/電池,汽車及零部件,電氣

詳細介紹

 

高靈敏度毫米波功率計Features  
  • 0.01-220 GHz operating frequency

  • High sensitivity

  • Up to 55 dB dynamic range (0.1uW-30mW)

  • Small measuring time (< 1 sec)

  • RS-232, GPIB interface

  • SCPI protocol

高靈敏度毫米波功率計Applications  
  • Recommended for use by Rohde & Schwarz

  • Measurements of power level of mm-wave signal

  • Test equipment

Description

The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.

DPM-xx Power Meters display measured power in milliWatts, microWatts or dBm, and also display the user-entered signal frequency in GHz. Easy operation is ensured with automatic zeroing, automatic sensor recognition and a calculation factor table stored in the memory of each power sensor.

Their compact size, precise accuracy, reliability and inexpensive pricing make our DPM-xx Power Meters attractive assets for design engineering, equipment manufacturing, field engineering and research.

ELVA-1’s ZBD-series Zero-Biased Detectors are used as the power sensors for our DPM Power Meters.To cover the range from 10MHz to 220GHz band, we offer one coaxial (10 MHz-26.5 GHz) and 9 waveguide power sensors (26.5-220 GHz in waveguide bands), sold separay.

Based on Schottky Barrier Diode technology, our ZBD power sensors provide high sensitivity, fast measurement speed and quick response to changes of input power. To extend the dynamic range of diode power sensors above their square law region, a correction factor is used. The amplitude and frequency curves for each individually-calibrated power sensor are stored in the sensor’s EEPROM. When a sensor is connected to a DPM control/display unit, the control/display unit automatically recognizes that sensor’s characteristics. The typical curves for amplitude and frequency transfer characteristics at W-band are shown on the reverse.

Measured average power is displayed on a 2-line LCD screen, at a measurement rate of 2 times per second or faster. For power measurements below 10-100mW (depending on frequency band), each sensor is supplied with a full-band isolator. For power measurements above those levels (as high as 300mW-1Watt), optional directional couplers are available.

Every DPM-xx is equipped with an RS-232 port for control and measurement data exchange with a PC. An internal GPIB interface board is available as an added option. On special request we can also provide a dual channel power meter of DPMD-XX series with two independent measurement channels.

Since the control/display unit and power sensors are sold separay, customers only need one DPM control/display unit to interface with all 10 of our sensors. To obtain power measurements over a multi-waveguide frequency range, order one DPM control/display unit and several adjacent-band sensors.  Because the standard ELVA-1 DPM control/display unit is a single-channel meter, only one power sensor can be used at one time.

 

DPM-XX Key Features and Specifications

- Display readings: milliWatts, microWatts or dBm

- Maximum measuring rate: up to 50 times per second, default 2 times per second (set at factory)

- Frequency Range: 10 MHz to 220 GHz

- Min. measured Power: 0.1 microWatt (depending on frequency band)

- Dynamic Measurement Range: 55dB max. (depending on frequency band)

- Frequency step: 10 MHz

- SCPI or ELVA’s command protocol

- RS-232, GPIB interface

- Calibration accuracy ±0.04 dB (log) or ±1%

- Power Sensor Calibration: Individually calibrated, with amplitude and frequency curves in flash memory

- If a valid signal frequency is not entered before measuring power, maximum measurement error will be ±1.5dB for Ka, Q, U, V bands, ±2.0dB for E, W bands, and ±2.5dB for F, D bands, based on calibration curve flatness.

Model Number DPM-C DPM -28 DPM -22 DPM -19 DPM -15 DPM -12 DPM -10 DPM -08 DPM -06 DPM -05
Frequency Band Ka Q U V E W F D G
Frequency Range, GHz 0.01-26.5 14757 33-50 40-60 50-75 60-90 75-110 90-140 110-170 140-220
Input Waveguide/Impedance 50 Ohm, Coaxial WR-28 WR-22 WR-19 WR-15 WR-12 WR-10 WR-08 WR-06 WR-05
Wavequide Flange/Connector SMA, male UG-599/U UG-383/U UG-383/U-M UG-385/U UG-387/U UG-387/U-M UG-387/U-M UG-387/U-M UG-387/U-M
Dynamic Range, dB (max) 50 55 55 55 55 55 55 55 50 40
Min Measured Power Level, dBm -33 -43 -43 -43 -43 -43 -40 -40 -35 -25
Measurement Rate (default), times per sec 2 2 2 2 2 2 2 2 2 2
VSWR (power sensor) 1.2:1 1.3:1 1.3:1 1.3:1 1.3:1 1.4:1 1.4:1 1.4:1 1.4:1 1.4:1

Available operating power options: 220 VAC, 110/100 VAC, or battery power (for portable version).

 

產品咨詢

留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7

全國統一服務電話

021-62209657

電子郵箱:sales@eachwave.com

公司地址:上海市閔行區劍川路955號707-709室

業務咨詢微信

主站蜘蛛池模板: 久久精品国产久精国产思思| 成人国内精品久久久久影院vr| 日本无码v视频一区二区| 国产三级无码内射在线看| 欧美黑人性暴力猛交喷水黑人巨大 | 秋霞人妻无码中文字幕| 亚洲国产成人久久综合三区| 中国内地毛片免费高清| 免费无码黄网站在线观看| 国产精品538一区二区在线| 欧美v成 人在线观看| 久久久久久av无码免费看大片| 亚洲国产欧美日韩精品一区二区三区 | 好吊视频一区二区三区| 国产极品视觉盛宴| 欧美日韩在大午夜爽爽影院| 国产精品第12页| 国产亚洲曝欧美精品手机在线| 人妻丝袜乱经典系列| 欧美大片18禁aaa片免费| 麻豆第一区mv免费观看网站| 北条麻妃在线一区二区| 东京热无码国产精品| 男女性动态激烈动全过程| 一卡二卡3卡4卡视频免费播放| 偷柏自拍亚洲综合在线| 午夜精品久久久久久毛片| 亚洲区小说区激情区图片区| 男人的天堂无码动漫av| 精品aⅴ一区二区三区| 少妇脱了内裤让我添| 久久精品国产亚洲αv忘忧草| 中文字幕乱人伦高清视频 | 亚洲愉拍99热成人精品热久久| 亚洲欧洲无码一区二区三区| 国产免费人成网站x8x8| 久久这里只有精品首页| 日本丰满熟妇videossex| 好大好硬好爽免费视频| 久久人人妻人人爽人人爽| 青青热在线精品视频免费观看|